The FLIR E54 is your entry into the Exx-Series, offering the resolution and sensitivity you need for basic condition monitoring, electrical/mechanical inspection, and building inspection. The 320 × 240 pixel thermal detector accurately measures temperatures up to 650°C (1202°F) and produces crisp, vibrant imagery that can be enhanced with patented FLIR MSX® technology for added detail and perspective. Onboard FLIR Inspection Route feature runs pre-planned survey routes to help inspectors stay organized when surveying large or multiple locations. For a limited time, the purchase of an E54 camera includes a 3-month subscription to FLIR Thermal Studio Pro and FLIR Route Creator.
-
IMPROVED CONTRAST FOR FASTER TROUBLESHOOTING Use FLIR 1-Touch Level/Span to instantly improve image contrast and highlight potential electrical or mechanical issues. -
FEATURES TO HELP WITH DIAGNOSIS The E54 measures up to 650°C (1202°F), offers 3 spotmeters, and displays the max/min temperature within an area live, on-screen. -
STREAMLINED REPORTING Onboard integration with FLIR routing software*, a built-in mic for voice annotation, and report generation features all help the E54 streamline your workday.
Description
Technical Specification
Imaging and optical data | |
Infrared resolution | 320 × 240 pixels |
NETD | <40 mK @ +30°C (+86°F) |
Field of view | 24° × 18° |
Minimum focus distance | 0.15 m (0.49 ft.) |
Minimum focus distance with MSX | 0.5 m (1.64 ft.) |
Focal length | 17 mm (0.67 in.) |
Spatial resolution (IFOV) | 1.31 mrad/pixel |
Lens identification | Automatic |
f number | 1.3 |
Image frequency | 30 Hz |
Focus | Manual |
Field of view match | Yes |
Digital zoom | 1–4× continuous |
Detector data | |
Focal plane array/spectral range | Uncooled microbolometer/7.5–14 µm |
Detector pitch | 17 µm |
Image presentation | |
Resolution | 640 × 480 pixels (VGA) |
Surface brightness (cd/m2) | 400 |
Screen size | 4 in. |
Viewing angle | 80° |
Color depth (bits) | 24 |
Aspect ratio | 04:03:00 |
Auto-rotation | Yes |
Touchscreen | Optically bonded PCAP |
Display technology | IPS |
Cover glass material | Dragontrail® |
Programmable buttons | 1 |
Viewfinder | No |
Image adjustment | Automatic Automatic maximum Automatic minimum Manual |
Image presentation modes | |
Infrared image | Yes |
Visual image | Yes |
Thermal fusion | No |
MSX | Yes |
Picture in Picture | Centered infrared area on the visual image |
Gallery | Yes |
Measurement | |
Camera temperature range | –20 to 120°C (–4 to 248°F) 0 to 650°C (32 to 1202°F) |
Object temperature range and accuracy (for ambient temp. 15 to 35°C (59 to 95°F) | Range –20 to 120°C (–4 to 248°F): –20 to 100°C (–4 to 212°F): ±2°C (±3.6°F) 100 to 120°C (212 to 248°F): ±2% Range 0 to 650°C (32 to 1202°F): 0 to 100°C (32 to 212°F): ±2°C (±3.6°F) 100 to 650°C (212 to 1202°F): ±2% |
Screening mode | |
Sampling average mode | Recommended temperature range: 30 to 45°C (86 to 113°F) in stable room temperatureAccuracy (drift): ±0.3°C (±0.5°F)1 |
Inspection mode | |
FLIR Inspection route | Enabled in the camera |
Measurement analysis | |
Spotmeter | 3 in live mode |
Area | 1 in live mode |
Automatic hot/cold detection | Auto-maximum/minimum markers within area |
Measurement presets | No measurements Center spot Hot spot Cold spot 3 spots Hot spot–Spot |
Difference temperature | Yes: as preset (Hot spot–Spot) |
Reference temperature | Yes: in preview mode |
Emissivity correction | Yes: variable from 0.01 to 1.0 or selected from materials list |
Measurement corrections | Yes |
External optics/windows correction | Yes |