The FLIR E85 is packed with the high-performance features needed for fast, accurate detection of hot spots and hidden deficiencies. The 384 x 288 true native resolution offers more than 110,000 points of temperature measurement, while the laser distance meter provides data for measuring square area (m² or ft²) on-screen.

SKU: 78501-0201 Categories: ,

Description

Technical Specifications

Imaging and optical data
Infrared resolution 384 × 288 pixels
UltraMax (super-resolution) Yes
NETD <50 mK @ +30°C (+86°F)
Field of view 14° × 10°
Minimum focus distance 1.0 m (3.28 ft.)
Minimum focus distance with MSX 1.0 m (3.28 ft.)
Focal length 29 mm (1.41 in.)
Spatial resolution (IFOV) 0.63 mrad/pixel
Available extra lenses 42° (AutoCal)
24° (AutoCal)
Lens identification Automatic
f number 1.5
Image frequency 30 Hz
Focus Continuous LDM
One-shot LDM
One-shot contrast
Manual
Field of view match Yes
Digital zoom 1–4× continuous
Detector data
Focal plane array/spectral range Uncooled microbolometer/7.5–14 µm
Detector pitch 17 µm
Image presentation
Resolution 640 × 480 pixels (VGA)
Surface brightness (cd/m2) 400
Screen size 4 in.
Viewing angle 80°
Color depth (bits) 24
Aspect ratio 04:03:00
Auto-rotation Yes
Touchscreen Optically bonded PCAP
Display technology IPS
Cover glass material Dragontrail®
Programmable buttons 1
Viewfinder No
Image adjustment Automatic
Automatic maximum
Automatic minimum
Manual
Image presentation modes
Infrared image Yes
Visual image Yes
Thermal fusion No
MSX Yes
Picture in Picture Resizable and movable
Gallery Yes
Measurement
Camera temperature range –20 to 120°C (–4 to 248°F)
0 to 650°C (32 to 1202°F)
300 to 1200°C (572 to 2192°F)
Object temperature range and accuracy (for ambient temp. 15 to 35°C (59 to 95°F) Range –20 to 120°C (–4 to 248°F):
–20 to 100°C (–4 to 212°F): ±2°C (±3.6°F)
100 to 120°C (212 to 248°F): ±2%
Range 0 to 650°C (32 to 1202°F):
0 to 100°C (32 to 212°F): ±2°C (±3.6°F)
100 to 650°C (212 to 1202°F): ±2%
Range 300 to 1200°C (572 to 2192°F): ±2%
Screening mode
Sampling average mode Recommended temperature range: 30 to 45°C (86 to 113°F) in stable room temperatureAccuracy (drift): ±0.3°C (±0.5°F)1
Measurement analysis
Spotmeter 3 in live mode
Area 3 in live mode
Automatic hot/cold detection Auto-maximum/minimum markers within area
Measurement presets No measurements
Center spot
Hot spot
Cold spot
User preset 1
User preset 2
Difference temperature Yes
Reference temperature Yes
Emissivity correction Yes: variable from 0.01 to 1.0 or selected from materials list
Measurement corrections Yes