The FLIR TG275 Automotive Diagnostic Thermal Camera combines non-contact temperature measurement and thermal imaging into one troubleshooting tool to help you quickly find the source of heat-related problems and spot potential faults when performing automotive maintenance and repair.
Key Features
- See beyond the limitations of single-spot IR thermometers with a 160 × 120 (19,200 pixel) true thermal imager.
- FLIR patented MSX enhancement adds sharp visual detail to thermal images, making it easier to diagnose problems.
- Measure a wide range of temperatures, from –25°C to 550°C (–13°F to 1022°F).
- Multipoint Laser pointer provides a circle to clearly show the area you are measuring.
- Rugged and reliable with an IP54 enclosure that protects the camera from dirt, dust, and oil.
Description
Technical Specifications
Imaging and optical data | |
IR resolution | 160 × 120 pixels |
Digital image enhancement | Yes |
Thermal sensitivity/NETD | < 70 mK |
Field of view (FOV) | 57° × 44° |
Minimum focus distance | 0.3 m (0.98 ft.) |
Distance to spot ratio | 30:01:00 |
Pseudo dual range | Range 1 < 400°C (< 752°F); Range 2 > 400°C (> 752°F) |
Image frequency | 8.7 Hz |
Focus | Fixed |
Detector data | |
Focal plane array/spectral range | Uncooled microbolometer/7.5–14 µm |
Detector pitch | 12 μm |
Image presentation | |
Display resolution | 320 × 240 pixels |
Surface brightness (cd/m2) | 400 |
Screen size | 2.4 in. portrait |
Viewing angle | 80° |
Color depth (bits) | 24 |
Aspect ratio | 04:03:00 |
Display technology | TFT |
Cover glass material | Optical grade silicon |
Image adjustment | Automatic |
Image modes | MSX (Multi Spectral Dynamic Imaging) Visual with temperature reading |
Gallery | Yes |
Measurement | |
Object temperature range | –25 to 550°C (–13 to 1022°F) |
Object temperature range and accuracy(ambient temp. 15 to 35°C (59 to 95°F)) | –25 to 0°C (–13 to 32°F), acc. ±3°C (±7°F) |
0 to 50°C (32 to 122°F), acc. ±2.5°C (±5°F) | |
50 to 100°C (122 to 212°F), acc. ±1.5°C (±3°F) | |
100 to 500°C (212 to 932°F), acc. ±2.5% | |
500 to 550°C (932 to 1022°F), acc. ±3% | |
IR temperature resolution | 0.1℃ (0.2°F) |
Repeatability of reading | ±1% of reading or ±1℃ (2℉), whichever is greater |
Response time | 150 ms |
IR thermometer measurement | Continuous scanning |
Minimum measurement distance | 0.26 m (0.85 ft.) |
Type-K range | –30 to 390°C (–22 to 734°F) ± (1.0% + 3°C (+7°F))(kitted Type-K probe is up to 260°C (500°F)) |
Maximum voltage at thermocouple input | 60V DC or 24Vrms AC |
00000″ align=”left”>0.26 m (0.85 ft.)